- Project period
- Q2 2026
- Industry
- Oil & Gas
- Application
- Hydrocarbon processing complex
- Equipment
- WIKA IPT-20 pressure transmitters
- Proposed configurations
- Cooling elements, diaphragm seals and capillary lines
- ADRIIX scope
- Equipment selection
- Status
- In operation
- Customer
- Not named
Process Conditions
The complex needed to measure pressure at several points with different design temperatures. The connection at each point had to limit heat transfer to the transmitter.
How Temperature Shaped the Selection
The proposal included cooling elements and diaphragm seals for points with elevated process temperatures. For the hottest points, ADRIIX proposed a diaphragm seal with a capillary line so the transmitter could be mounted farther from the hot process connection.
Project Result
The selected WIKA pressure measurement equipment is in operation at the complex.
Equipment Reference
WIKA documents the IPT-20 transmitter and explains how capillary lines are used in pressure measurement assemblies.